Queens University Biosciences Rooms 2311 & 2305 Renovations

Closed - Bids/Quotes/Tenders (Award/Short List - Not Available)
Public
18-01125
0048111919
116 Barrie Street,  Kingston ON
(Frontenac) , Canada
General Building
Educational
College/University
Renovation
Multiple
December 03, 2019 3:00 PM   -  
Electronic Bid Submission Required via Email to: jt94@queensu.ca
Subcontractors wishing to obtain documents and submit a bid should contact the
selected Prequalified Contractors for additional information.
Please Contact the Issuing Authority for Future Information Regarding this Project.

Site  -  A Site Visit may be Required to Bid this Project.
Subcontractors should contact the Prequalified General Contractors for Additional Information.
Estimate Not Available

Renovations to Biosciences Rooms 2311 & 2305

The objectives of this project are to:
• create a modern laboratory room for 40 students
• design the room to facilitate a ‘student-centered’ learning experience
• have students work in pods with 4 students per pod
The room would be equipped with a student side bench a prep bench student pods safety station student side bench and storage. A/V requirements.

Demolition and construction: As per Architectural drawing A2.

Lab Elements:
• Safety station and the coat racks at the entrance. The labs electrical panel and gas shut off should be located outside in the corridor.
• Student pods with electrical outlets nitrogen turret with a needle valve video with speakers. The pods that show as islands will need to have their servicing brought up from below while the pods that are peninsulas can have their services side loaded from the wall.
• Student side benches serviced with vacuum compressed air nitrogen and natural gas. The sink has a hot and cold water gooseneck as well as a gooseneck for type II water. Cupboards drawers bench overhead cabinets.
• Teaching pod with cabinets: intended to be a lectern A/V cabinet and demonstration space.
• Existing piped Services – volumes and pressures to be confirmed.
• Electrical – Duplex receptacles GFCI duplex receptacles in addition to provision for future needs. The conduit should be slightly oversized to accommodate future pulls.
• Ventilation ducting and fireproofing.
• Lighting
• Materials: Flooring wall finishes bench tops millwork and doors.
• Ceiling panels.

Jamie Thompson
Project Manager
Phone: (613) 533 2127
Email: jt94@queensu.ca

Substantial Completion: May 11, 2020

50 %
50 %
Required

Prequalified General Contractors Only.

Queens University

DOW's
Division 02 - Existing Conditions
Existing Conditions
Division 06 - Wood, Plastics and Composites
Wood, Plastics and Composites, Millwork
Division 08 - Openings
Openings, Doors and Frames
Division 09 - Finishes
Finishes, Ceilings, Flooring, Plaster and Gypsum Board
Division 10 - Specialties
Specialties, Wardrobe and Closet Specialties
Division 12 - Furnishings
Furnishings
Division 22 - Plumbing
Plumbing
Division 23 - HVAC
HVAC
Division 26 - Electrical
Electrical
Division 27 - Communications
Communications
Confirmed By Brennen Kliffmueller